Just learn how loads work and act smartly, don't just overload to the point of a house fire. Don't misuse a 30A breaker where a 15A or 20A breaker should be used, like powering common lighting and receptacle circuits. The only legitimate use I have seen is in TT30 sockets for small travel trailers. Wait, did you say 110V?Ī 110/120V circuit that is 30A is extremely rare. Label the socket "GFCI Protected / No Equipment Ground".


If you absolutely, insist on wiring it 3-wire without ground, then still use a NEMA 14-30 socket and plug, and fit a 2-pole GFCI breaker in the panel.
#Eaton br 200 amp breaker install#
However, if your appliance comes with a NEMA 6-30 plug, you are allowed to install a NEMA 6-30 receptacle instead of 14-30 it'll be grounded and you won't use the neutral. If you are hooking up a dryer and the dryer came to you with a NEMA 10-30 cord and plug, then change the cord and plug to NEMA 14 while removing the neutral-ground jumper on the dryer.

You are not allowed to install the obsolete/dangerous NEMA 10-30 (3-prong) which has no ground.
#Eaton br 200 amp breaker series#
They are designed for a wide range of applications such as high short-circuit interrupt, series rating combinations with upstream main breakers, thermal magnetic, AFCI, GFCI, equipment protection and dual function AF/GF. Anti - restriking oil circuit breaker having an anti - cavitation device. It for use with overhead/underground feed applications and features a ringless socket. Eaton’s BR circuit breakers are used in indoor and outdoor BR loadcenters, spa panels, meter breakers and sub panels. If this is going to a receptacle, it needs to be a NEMA 14-30 (4-prong) type receptacle. The Eaton type BR 200-amp 120/240 VAC outdoor meter sockets four-space/eight-circuit with 200-amp main breaker and feed-through lugs. Then ground to the panel chassis or a ground bar (which would be empty), you can buy retrofit ground bars for most panels for $5-ish. This happens when the wiring is done in metal conduit, and the grounding is via the metal conduit. In some cases there is a neutral and not a ground bar. DO NOT DO THIS unless you see all other circuits also doing this! In some cases, the neutral bar will be the same thing as the ground bar, and all neutrals and grounds will be clumped onto the same bar. Get Eaton Type BR 200-Amp 4-Spaces 8-Circuit Main Breaker Meter Combo Load Center delivered to you in as fast as 1 hour via Instacart or choose curbside or. There will be a bunch of other white wires also going to this bar. Eaton’s Type BR 3-phase loadcenter product line is a reliable solution for light commercial projects where the flexibility of plug-on branch breakers is desired. The neutral bar is a closely packed row of screws which capture wires underneath them.
#Eaton br 200 amp breaker professional#
New features that help ensure an aesthetically clean and professional installation. Designed to maximize installation efficiency and to provide additional convenience allowing for an easy installation. Time saving features offer a quick installation equating to less time on the job. Eatons meter breakers combine a single meter socket and a main circuit breaker and/or loadcenter into one enclosure. Quick, easy and clean describe the new plug-on neutral design attributes offered by Eaton.